Guidelines
HBA of Greater Dallas Green Building Elements
Site Management and Waste Recycling
- Obtain TCEQ Storm Water Permit and follow best management practices.
- Implement a tree protection plan or fully comply with established local ordinance regarding tree protection.
- Establish jobsite recycling plan to include lunch trash, and require subcontractor participation to minimize construction waste, sort waste, and maximize material recycling where available.
Water Efficiency
- Install rain and freeze sensors on sprinkler system.
- Install hot water on demand system or locate water heater within 30 ft. of fixtures.
- Select water efficient toilets that work with first flush (min. 250 grams).
- Select lavatory faucets with less than 2.0 gpm, and select kitchen & utility faucets with less than 2.2 gpm.
- Select shower heads with less than 2.5 gpm.
- Limit landscape & turf plantings to droughttolerant varieties (unless prevented by customer selection), or install rainwater catchment system to provide for a minimum 50% of landscape irrigation needs.
- Install 2" deep mulch in landscape beds.
Indoor Air Quality
- Perform Manual J calculation based on actual house design, specifications and orientation and ensure that installed equipment matches Manual J calculations. Perform refrigerant level test. Provide all
documentation to the homeowner.
- Seal ducts during construction at vent entry and exit.
- Provide ducted mechanically controlled fresh air in-take system sufficient to meet the fresh air needs of the house.
- Provide power venting or sealed combustion providing fresh air for gas furnaces and water heaters located in conditioned space. Or install heat pump.
- Install continuous drainage plane on exterior walls behind cladding material.
- No vapor barrier on inside of exterior walls.
- Ensure proper flashing at windows and doors.
- Install kitchen range hood and vent to outside.
- Provide combustion air for fireplaces from outside.
- Use no fiberglass duct board unless sealed properly with low toxic mastic.
- Install return air ducts or jumper ducts in all bedrooms.
- Install vapor barrier under slab.
- Install capillary break under bottom plate.
- Use min. 1" pleated filters for AC return.
- One carbon monoxide (CO) detector, hardwired, shall be installed per 1,000 sq. ft. of living space (minimum one per floor).
- Avoid an attached garage or isolate the garage from the living space with appropriate sealing techniques.
Energy Efficiency
- Energy Star Certified.
- Minimize window exposure on east & west or shade windows facing east & west.
- Install Energy Star appliances unless prevented by customer selection.
- Install radiant barrier, light-colored roof, or insulated roof deck.
Materials
- Use engineered lumber products to maximum extent possible to include trusses, joists and finger-jointed dimensional lumber.
- Use exterior cladding materials with minimum 25-year warranty.
- Provide gutter downspout extensions and positive drainage away from house.
- Employ advanced framing techniques to reduce waste.
Homeowner Education
- Provide homeowner with operations and maintenance kit and perform walkthrough.
- Provide homeowner with local recycling opportunities.
- Provide information on green energy service providers.
- Provide basic information on Energy Star program, ratings/certification.